MAGNA™ THERMAX FLUID
MAGNA™ THERMAX FLUID
MAGNA THERMAX FLUID-High quality oil designed with VI paraffinic oil and specially selected chemical additive system which imparts low vapor pressure, high thermal stability, specific, heat and thermal conductivity to the oil.
SPECIFICATIONS
BS 489:1983
DIN 51515
GENERAL ELECTRIC GE-K-32568A/B
BROWN BOVERI HT GD 90117E
ALSTHOM ATLANTIQUE NBA P50001
Links of Interest
Features & Benefits
Excellent resistance to sludging and fouling in the heat transfer zone
Superior fluidity at low temperatures enables easy and uninterrupted circulation
High thermal and oxidation stability, even at elevated operating temperatures
Long-term rust and corrosion protection for internal system components
Consistent and efficient heat transfer, ensuring optimal system performance over time
Applications
MAGNA THERMAX FLUID Recommended for non-pressurized, closed liquid phase heating systems operating up to 310 C. such systems are widely used in the food, construction, plastic, timber, asphalt plants metal industries as well as laundries, ships and where waste heat is extracted from flue gases
Typical Characteristics
| THERMAX FLUID (ISO) | 32 | 46 | 68 | 100 |
|---|---|---|---|---|
| Density @ 15°C Kg/m³ | 874 | 877 | 891 | 894 |
| Kinematic viscosity, 40°C cSt | 32 | 46 | 68 | 100 |
| Kinematic viscosity, 100°C cSt | 5.5 | 6.7 | 8.7 | 11.3 |
| Viscosity Index | 102 | 101 | 100 | 100 |
| Flash point, COC, °C | 220 | 224 | 232 | 236 |
| Pour point, °C, Max | -12 | -10 | -9 | -9 |
| Fire point, COC, °C | 243 | 243 | 241 | 240 |
| Autoignition temperature, °C | 345 | 345 | 345 | 345 |